Hygroscopic Test Results
Product: HR-Prof
Application: 3 coats = 300g m2
Tests carried out by: SP Technical Research Institute of Sweden: SP Trätek 060926 LT
Customer: Nordic House Finland
Tests to: NT Build 504
Product |
Moisture (%) |
Comments |
23 ˚C, 50 % RH |
27 ˚C, 90 % RH |
Pine |
12,1 |
20,7 |
Surface of the sample unchanged |
Treated Pine |
14,0 |
26,6 |
Surface of the sample unchanged |
Kerto LVL |
9,6 |
17,4 |
Surface of the sample unchanged |
Treated Kerto LVL |
9,9 |
18,1 |
Surface of the sample unchanged |
|